CHINA

WAVE2 Digital Storage Oscilloscope

JYE Tech WAVE2 is a portable dual-channel digital storage oscilloscope featuring 200kHz bandwidth, 1MS/s sampling per channel, 12-bit resolution, a 2.4-inch touchscreen and a built-in dual-channel DDS function generator.

Flychip Semiconductor Solutions 20 Years

Your reliable partner for semiconductor solutions. Flychip supports customers from R&D to mass production with electronic component supply, BOM sourcing, PCB, SMT and PCBA services.

20+
Years Component Supply
BOM
Multi-Part Sourcing
PCBA
PCB / SMT Support
Part No.:
WAVE2 Digital Storage Oscilloscope
Manufacturer:
CHINA
Category:
Electrical
Package:
Datasheet:

-

Description:
JYE Tech WAVE2 is a portable dual-channel digital storage oscilloscope featuring 200kHz bandwidth, 1MS/s sampling per channel, 12-bit resolution, a 2.4-inch touchscreen and a built-in dual-channel DDS function generator.
Quantity:
Quality Control

Supplier review, channel management and product verification before delivery.

Global Channels

International chip manufacturer and well-known distributor sourcing network.

BOM to Production

Component supply support from R&D prototype to mass production.

PCB / SMT / PCBA

Integrated manufacturing support to accelerate product development and delivery.

Product Details

FLYCHIP · TEST & MEASUREMENT ENGINEERING REVIEW

JYE Tech WAVE2 Dual-Channel Portable Digital Storage Oscilloscope

The JYE Tech WAVE2 is a compact two-channel portable digital storage oscilloscope designed for electronics education, embedded development, signal observation and low-frequency circuit troubleshooting. It combines a 200kHz analog bandwidth, 1MS/s real-time sampling per channel, 12-bit vertical resolution and a 2.4-inch color touchscreen. A built-in dual-channel DDS function generator, Y-T and X-Y display modes, waveform memory and serial data communication provide additional functions in a portable measurement platform.

JYE TECH WAVE2 2 CHANNELS 200kHz BANDWIDTH 1MS/s PER CHANNEL 12-BIT RESOLUTION 2.4-INCH TOUCHSCREEN BUILT-IN DDS
Analog Bandwidth 200kHz Per channel
Sampling Rate 1MS/s Maximum real-time, per channel
Vertical Resolution 12-bit Digital acquisition resolution
Display 2.4" 320 × 240 color touchscreen
01
Product Overview

WAVE2 Portable Digital Storage Oscilloscope

WAVE2 is a two-channel digital storage oscilloscope developed by JYE Tech Ltd. It is designed for users who need a compact instrument for observing electrical waveforms, comparing two signals and performing basic electronic measurements without using a conventional full-size bench oscilloscope.

The instrument supports both Y-T and X-Y display modes. Y-T mode displays signal amplitude against time, while X-Y mode displays the relationship between two input signals. These functions are useful for examining periodic waveforms, signal phase relationships and basic electronic circuits.

In addition to waveform acquisition, WAVE2 integrates a dual-channel DDS function generator. This provides a convenient source for generating basic test signals during circuit development and laboratory exercises. The instrument also supports on-screen measurements, waveform save and recall, and serial data output.

Product identification: The supplied product photograph shows the WAVE2 handheld oscilloscope, packaging, quick-start documentation and BNC-style test accessories. JYE Tech is the manufacturer identified in the manufacturer's product documentation.
Product Characteristics
Two-Channel Measurement

Observe two electrical signals through separate CH1 and CH2 BNC input connections.

Portable Design

Compact handheld construction for bench-side testing, classroom use and field troubleshooting.

Touchscreen Operation

A 2.4-inch color display with touch control and a multifunction adjustment dial.

Integrated Signal Generator

Dual-channel DDS signal generation is available through the auxiliary connector.

Product Identification
Item Product Information Engineering Description
Manufacturer JYE Tech Ltd. Electronic test instrument manufacturer
Product Model WAVE2 Portable digital storage oscilloscope
Product Category Digital Oscilloscope Test and measurement equipment
Channel Configuration Dual Channel Two independent signal inputs
Display 2.4-inch Color Touchscreen 320 × 240 pixel display
Acquisition Digital Storage Waveform capture and memory functions
Additional Function Dual-Channel DDS Built-in signal generation
02
Technical Specifications

WAVE2 Electrical and Performance Specifications

WAVE2 is designed for low-frequency waveform observation and basic signal analysis. Its specifications should be evaluated as a complete measurement system, including analog bandwidth, sampling rate, input characteristics, trigger behavior and probe attenuation.

General Specifications
Parameter Specification Engineering Meaning
Product Model WAVE2 JYE Tech portable oscilloscope
Number of Channels 2 Dual-channel signal observation
Analog Bandwidth DC to 200kHz Specified analog measurement bandwidth
Maximum Sampling Rate 1MS/s per channel Maximum real-time sampling rate
Vertical Resolution 12-bit Digital conversion resolution
Record Length 1024 points Waveform acquisition buffer
Display Size 2.4 inches Color display with touch operation
Display Resolution 320 × 240 QVGA-class color display
Display Modes Y-T and X-Y Time-domain and signal relationship plots
Waveform Memory 4 memory blocks Save and recall captured waveforms
Vertical System Specifications
Parameter Specification Notes
Input Channels CH1 and CH2 Two BNC signal inputs
Bandwidth DC–200kHz Per channel
Sensitivity 5mV/div–20V/div Using x1 probe
Sensitivity Error Less than 5% Manufacturer specification
Vertical Resolution 12-bit Digital resolution
Input Impedance 1MΩ / 25pF Input loading characteristic
Maximum Input Voltage 50Vpk Observe probe and instrument ratings
Input Coupling AC / DC Selectable input coupling
Horizontal System Specifications
Parameter Specification Application
Maximum Real-Time Sampling 1MS/s per channel Signal acquisition
Time Base Range 10µs/div–500s/div Fast and slow waveform observation
Record Length 1024 points Digital waveform storage buffer
Display Modes Y-T / X-Y Time and phase-related analysis
Bandwidth limitation: WAVE2 has a specified analog bandwidth of 200kHz. It should not be selected as a replacement for MHz-bandwidth or high-speed digital oscilloscopes. Sampling rate and analog bandwidth are different specifications and must be considered separately.
03
Input & Measurement Architecture

Dual-Channel BNC Input and Vertical Measurement Design

The WAVE2 provides two analog input channels, identified as CH1 (Y) and CH2 (X). Both channels can be used to observe electrical signals and compare waveform behavior. This configuration is particularly useful when examining input and output signals, reference and response waveforms or two related circuit nodes.

Channel Configuration
Input Connection Function Typical Use
CH1 (Y) BNC First analog input Reference or primary signal
CH2 (X) BNC Second analog input Comparison or secondary signal
Coupling AC / DC Input signal coupling Signal observation and offset analysis
Probe BNC Probe Signal connection Electrical measurement
Built-In Measurement Functions
Vmax / Vmin

Displays the maximum and minimum measured signal voltage within the captured waveform.

Vavr

Calculates the average voltage value of the selected waveform.

Vpp

Measures peak-to-peak voltage between the waveform's maximum and minimum levels.

Vrms

Provides root-mean-square voltage measurement for signal analysis.

Frequency

Measures the prominent frequency of the observed signal.

Duty Cycle

Supports duty-cycle observation for suitable periodic waveforms.

Measurement recommendation: Select an appropriate vertical scale, coupling mode and probe attenuation before measuring. Probe compensation and ground connection can affect the displayed waveform and measurement accuracy.
04
Acquisition & Trigger

Sampling Rate, Time Base and Trigger Control

WAVE2 uses digital waveform acquisition with a maximum real-time sampling rate of 1MS/s per channel. Its time-base range extends from 10µs/div to 500s/div, allowing users to inspect periodic signals and slower changing electrical behavior.

The acquisition buffer contains 1024 points. The available sampling rate, time base and displayed waveform detail should be considered together when choosing the measurement setup.

Trigger Specifications
Parameter Specification Function
Trigger Modes Auto / Normal / Single Different waveform acquisition behaviors
Trigger Types Rising / Falling Edge Edge-based triggering
Trigger Position Half buffer size Trigger reference position
Trigger Sources CH1 / CH2 / External Selectable trigger input
External Trigger Maximum 15V External trigger input rating
External Trigger Threshold LVTTL Logic-level trigger threshold
Basic Waveform Acquisition Sequence
Connect CH1 / CH2
Signal Inputs
→
Set Vertical Scale
and Time Base
→
Configure Trigger
Source and Edge
Acquire Signal
Waveform
→
Review Measurements
and Display
→
Save or Send
Captured Data
Sampling and aliasing: A 1MS/s sampling rate does not mean that every 1MHz input signal can be measured accurately. The 200kHz analog bandwidth, acquisition buffer and waveform characteristics limit the practical measurement capability. For signals with fast edges or higher-frequency components, use a suitable higher-bandwidth instrument.
05
Integrated Signal Generation

Built-In Dual-Channel DDS Function Generator

An important feature of WAVE2 is its integrated dual-channel direct digital synthesis (DDS) function generator. It allows the instrument to provide basic test signals through its auxiliary port without requiring a separate external signal generator for every simple measurement task.

The function generator supports sine, square, sawtooth and stair waveform types. The manufacturer specifies a sine-wave frequency range from DC to 20kHz, with an output amplitude range of 0 to 3V peak.

Function Generator Specifications
Parameter Specification Engineering Description
Generator Channels 2 Dual-channel DDS outputs
Waveform Types Sine / Square / Sawtooth / Stair Selectable waveform generation
Sine Frequency Range DC–20kHz Manufacturer specified sine-wave range
Output Amplitude 0–3V peak Peak output amplitude range
Output Offset 0V or +3.3V Selectable output offset
Duty Cycle 0–100% Adjustable waveform duty cycle
Phase -360° to +360° Phase adjustment range
Output Connection Auxiliary Port Dedicated generator output terminals
Typical Function Generator Applications
Amplifier Testing

Generate a suitable low-frequency signal to observe amplifier response and output waveform behavior.

Filter Evaluation

Apply basic test signals to low-frequency filter circuits and inspect their response.

Signal Comparison

Use the two-channel generator and X-Y display to investigate relationships between signals.

Educational Experiments

Provide simple generated waveforms for electronics teaching and laboratory exercises.

Output connection note: The generator outputs are provided through the auxiliary port. Check the official auxiliary connector pinout before connecting external circuits. Do not assume the generator output is available through the BNC oscilloscope inputs.
06
Display & Operation

Touchscreen Operation, Y-T and X-Y Display Modes

WAVE2 uses a 2.4-inch color touchscreen with a resolution of 320 × 240 pixels. The interface combines touch operation, four multifunction buttons and an adjustment dial. This arrangement provides access to waveform settings, measurement functions and instrument configuration menus.

Display and User Interface
Feature Specification Function
Display Size 2.4 inches Compact color display
Display Resolution 320 × 240 pixels Waveform and menu display
Touch Operation Supported Touchscreen parameter selection
Function Buttons F1–F4 Multifunction menu operation
Adjustment Dial Multifunction Parameter adjustment and navigation
Display Modes Y-T / X-Y Time-domain and relationship plotting
Y-T and X-Y Operating Modes
Y-T Mode

Displays signal voltage against time. This is the conventional oscilloscope view for examining waveform shape, frequency and timing behavior.

X-Y Mode

Displays the relationship between the CH1 and CH2 signals. It can be used for basic phase comparison and Lissajous pattern observation.

Waveform Storage and Recall

WAVE2 provides four waveform memory blocks. Users can save the last displayed waveform into a selected memory location and recall a previously stored capture for review. Captured data can also be sent through the serial interface.

Practical benefit: The combination of waveform memory, on-screen measurements and serial data output helps make WAVE2 useful for basic laboratory records, circuit comparison and learning exercises.
07
Power & Portability

USB Power, Rechargeable Battery and Portable Operation

WAVE2 supports USB power and a 3.7V lithium-ion battery supply. This dual power arrangement allows the instrument to be used on a workbench or in locations where a conventional bench power arrangement is inconvenient.

Power Specifications
Parameter Specification Notes
Power Sources USB / Li-ion Battery Two power options
Battery Voltage 3.7V Rechargeable lithium-ion battery
Operating Supply 3.7–5V Manufacturer stated supply range
Current Consumption Approximately 300mA At 3.7–5V
Battery Charger Optional / Revision Dependent Verify mainboard version
Automatic Power Off Supported on Battery Inactivity power management
Battery Runtime Approximately 3 hours When fully charged, manufacturer reference
Physical Specifications
Parameter Specification Remarks
Dimensions 115 × 72 × 30mm Compact handheld body
Weight Approximately 0.29kg Excluding battery and probes
Construction Portable handheld instrument Compact measurement equipment
Battery verification: Battery inclusion and charging functionality depend on the exact purchased version and mainboard revision. Confirm the battery, charging circuit and USB power arrangement before procurement. Do not assume every WAVE2 kit includes a battery.
08
Data Communication

Serial Interface, PC Data Transfer and Firmware Support

WAVE2 supports serial communication for captured waveform data output and instrument control. This feature can be useful when measurement data needs to be transferred to a computer for further processing or when the instrument is integrated into a simple automated test workflow.

Serial Communication Specifications
Parameter Specification Application
Interface Serial / UART Instrument data communication
Logic Level LVTTL Low-voltage digital interface
Baud Rate 115200bps Serial communication speed
Data Bits 8 Serial data format
Parity None No parity bit
Stop Bits 1 8N1 serial format
Captured Data Serial Output Transfer waveform information
Serial Control Supported Remote instrument control
Mainboard Revision Considerations

JYE Tech introduced an M-version mainboard designated 109-15800-00M. According to the manufacturer, this revision integrates the earlier battery charger and power-switch breakout-board circuits into the main PCB and adds a CH340N USB-to-UART converter.

The USB-to-UART implementation allows serial data transfer and firmware upgrading through the USB power connection. Earlier J-version boards have a different interface arrangement, so buyers should verify the actual PCB revision before expecting identical USB communication functionality.

Integration advice: The serial interface uses LVTTL-level signals. Do not connect the auxiliary UART signals directly to an RS-232 voltage-level interface. Use an appropriate USB-UART or level-conversion arrangement.
09
Application Engineering

Typical Applications for WAVE2

WAVE2 is intended for basic waveform observation, low-frequency signal analysis, educational experiments and embedded electronics development. Its dual-channel structure and integrated function generator provide a convenient combination for small-scale laboratory work.

Electronics Education

Demonstrate basic electrical waveforms, frequency, amplitude, phase and signal measurement principles.

Embedded Development

Observe low-frequency analog signals and basic sensor output behavior during microcontroller development.

Analog Circuit Testing

Inspect amplifier, oscillator and low-frequency filter waveforms within the instrument bandwidth.

Signal Comparison

Compare two related signals through dual-channel observation and X-Y display operation.

Low-Frequency Troubleshooting

Observe supply ripple, slow signal changes and other suitable low-frequency circuit behavior.

Basic Test Signal Generation

Generate low-frequency waveforms for circuit experiments using the integrated DDS function.

Application Suitability
Application Suitability Engineering Consideration
Low-Frequency Analog Circuits Suitable Observe the 200kHz bandwidth limit
Basic Amplifier Testing Suitable Check signal amplitude and bandwidth
Educational Experiments Suitable Useful for waveform learning
Sensor Signal Observation Suitable Check input voltage and coupling
Basic Frequency Comparison Suitable Use two channels and appropriate settings
High-Speed Digital Buses Not Recommended Bandwidth and sampling limitations
RF Signal Analysis Not Recommended Requires a higher-bandwidth instrument
High-Speed Switching Analysis Limited Fast edges may not be captured accurately
Application boundary: WAVE2 is a 200kHz portable oscilloscope. It should not be used for high-frequency RF, high-speed digital signal integrity, precision power electronics switching analysis or high-voltage measurement beyond its rated input and probe limits.
10
Engineering Selection

How to Evaluate WAVE2 Against Other Oscilloscopes

Selecting an oscilloscope should begin with the signal characteristics that need to be measured. Analog bandwidth, sampling rate, vertical resolution, record length, channel count, input voltage limits and trigger capabilities should be evaluated together.

Key Selection Factors
Selection Factor WAVE2 Specification Engineering Evaluation
Channel Count 2 Suitable for two-signal comparison
Bandwidth 200kHz Designed for low-frequency signals
Sampling Rate 1MS/s per channel Evaluate waveform timing requirements
Resolution 12-bit Evaluate voltage measurement requirements
Record Length 1024 points Limited capture buffer
Function Generator Dual-Channel DDS Useful for basic test signal generation
Portability USB / Battery Useful for mobile measurement tasks
PC Connectivity Serial Interface Check board revision and connection method
When to Choose a Higher-Specification Oscilloscope
Higher Analog Bandwidth

Select a faster instrument when measuring higher-frequency signals or fast transitions that exceed the WAVE2 bandwidth.

Longer Record Length

Choose a larger acquisition memory when long-duration captures or detailed waveform analysis are required.

Advanced Triggering

More complex digital, pulse-width and protocol-related analysis may require advanced trigger functions.

Higher Input Voltage

Select properly rated measurement equipment and probes when working with higher-voltage or industrial power circuits.

Engineering Approval Checklist
200kHz bandwidth meets the signal requirement
1MS/s sampling rate is sufficient
1024-point record length is acceptable
Two input channels meet the application need
Probe attenuation is correctly configured
Maximum input voltage is not exceeded
External trigger level is within rating
DDS output meets the test signal requirement
Battery or USB power arrangement is suitable
Serial interface revision is confirmed
11
Procurement EEAT

Manufacturer Verification, Product Revision and Supply Risk Control

WAVE2 is a JYE Tech instrument rather than a generic electronic component. Procurement teams should verify the manufacturer, exact ordering version, assembly status, mainboard revision and included accessories before approving a purchase.

The WAVE2 product family includes an assembled oscilloscope version identified as 15801 and a DIY kit identified as 15801K. These versions have different delivery contents and should not be treated as identical commercial SKUs.

Manufacturer and Procurement Information
Procurement Item Reference Information Verification Requirement
Manufacturer JYE Tech Ltd. Check manufacturer identification
Product Model WAVE2 Confirm model name on product and packaging
Assembled SKU 15801 Confirm assembled and tested condition
DIY Kit SKU 15801K Confirm unassembled kit contents
Mainboard Revision J / M versions Check PCB identification
Firmware Revision Dependent Check installed firmware version
Probe Accessories 2 BNC probes in documented packages Check probe model and attenuation
Battery SKU Dependent Confirm battery inclusion and condition
USB Cable Package Dependent Check packing list
Documentation Quick Start Guide Confirm documentation revision
Warranty Seller Confirmed Request actual warranty terms
Lifecycle Supplier Confirmed Verify current availability and support
Version and Mainboard Verification
J-Version Mainboard

Earlier board revision. Verify the actual serial interface and accessory arrangement before expecting USB-to-UART functionality.

M-Version Mainboard

Manufacturer update 109-15800-00M includes an integrated CH340N USB-to-UART converter and integrated board functions.

Incoming Quality Control
Confirm WAVE2 model identification
Inspect product body and display
Verify both BNC input connectors
Check two supplied probes if listed
Inspect BNC cables and probe condition
Verify USB power operation
Check battery operation when included
Test both input channels
Verify trigger and waveform display
Check DDS generator output
Verify serial communication when required
Record firmware and PCB revision
FLYCHIP procurement recommendation: For repeat purchases, maintain the exact SKU, mainboard revision, firmware version and accessory packing list in the approved procurement record. This reduces the risk of receiving a different configuration under the same WAVE2 product name.
12
Product Packaging

WAVE2 Package Contents and Accessory Verification

The supplied photograph shows a WAVE2 product package, the handheld oscilloscope, a quick-start guide, BNC-style test accessories and connecting cables. The visible contents provide a useful reference for product identification, but the final delivery configuration must be confirmed against the supplier's packing list.

Manufacturer-Listed Package Variants
Item 15801 Assembled Version 15801K DIY Kit
WAVE2 Main Unit 1 assembled and tested unit 1 DIY oscilloscope kit
BNC Probes 2 2 selectable x1/x10 probes
Quick Reference Guide Included Included
Assembly Guide Not listed in standard contents Included
Battery Included in manufacturer-listed package Not included in DIY kit
Assembly Requirement Ready assembled Assembly required
Visible Product Photo Checklist
WAVE2 Main Unit

Blue and white handheld oscilloscope with color display, function buttons and adjustment dial.

BNC Test Accessories

BNC-style connectors and test probes are visible in the supplied product photo.

Quick Start Documentation

Printed quick-start guide for instrument operation.

Packaging and Cables

Product boxes and connecting cables are shown in the supplied photograph.

Package-content notice: The supplied image is a product reference photograph, not a certified packing list. Confirm the exact probe model, USB cable, battery, battery wiring and other accessories with the seller before placing an order.
13
Frequently Asked Questions

WAVE2 Digital Oscilloscope FAQ

What is the JYE Tech WAVE2?
WAVE2 is a portable two-channel digital storage oscilloscope developed by JYE Tech. It combines waveform acquisition, basic measurement functions and a built-in dual-channel DDS function generator.
What is the bandwidth of WAVE2?
The specified analog bandwidth is DC to 200kHz per channel. It is designed for low-frequency waveform observation rather than high-frequency RF measurements.
How many channels does WAVE2 support?
WAVE2 has two analog input channels, CH1 and CH2, each using a BNC connection.
What is the maximum sampling rate?
The maximum real-time sampling rate is 1MS/s per channel according to the manufacturer specification.
What is the vertical resolution?
WAVE2 provides 12-bit vertical digital resolution. This is the conversion resolution and should not be confused with absolute measurement accuracy.
Does WAVE2 have a built-in signal generator?
Yes. It integrates a dual-channel DDS function generator with sine, square, sawtooth and stair waveform options. The specified sine-wave frequency range is DC to 20kHz.
What is the display size?
WAVE2 uses a 2.4-inch color touchscreen with a 320 × 240 pixel resolution.
Does WAVE2 support X-Y display mode?
Yes. It supports both Y-T and X-Y modes. X-Y mode can be used to observe the relationship between two input signals.
What is the maximum input voltage?
The manufacturer's listed maximum input voltage is 50Vpk. Always check the probe attenuation, probe voltage rating and instrument limits before connecting a signal.
Can WAVE2 operate without USB power?
Yes. It supports a 3.7V lithium-ion battery supply. Battery inclusion and charging features depend on the exact product version and board configuration.
Can captured waveforms be transferred to a PC?
Yes. WAVE2 supports serial data output and serial control. The specified serial format is LVTTL, 115200bps, 8N1. The USB-to-UART implementation depends on the mainboard revision.
What is the difference between 15801 and 15801K?
15801 is the assembled and tested oscilloscope version. 15801K is the DIY kit version and requires assembly. The DIY kit does not include a battery in the manufacturer's listed contents.
Is WAVE2 suitable for high-speed digital signals?
It is not recommended for high-speed digital signal integrity testing. Its 200kHz analog bandwidth and 1MS/s sampling rate are intended for low-frequency applications.
What accessories are included with WAVE2?
Manufacturer-listed packages include two BNC probes and a quick reference guide. The assembled and DIY versions differ in battery and assembly documentation. Confirm the exact packing list with the supplier.
14
Technical Evidence

Manufacturer Documentation and Engineering References

This product review is based on the JYE Tech WAVE2 product specification and manufacturer documentation. Electrical performance, acquisition capability, signal generation, physical dimensions and product version information are presented as manufacturer reference specifications.

The visible product photograph supports physical product identification and the observation of packaging and accessories. It does not independently establish the instrument's calibration status, production date, firmware version or electrical measurement accuracy.

Official Technical Resources
Engineering evidence boundary: Final product acceptance should be based on the actual supplied unit, its firmware and mainboard revision, accessory ratings, functional inspection and the manufacturer's published documentation. Calibration certification and warranty coverage should be confirmed separately.
Flychip Advantage

From Component Sourcing to Production Delivery

Flychip has been providing electronic components to global customers for 20 years. We combine component supply, BOM services, PCB, SMT and PCBA support to help customers accelerate product development and delivery.

R&D Support

Fast sourcing support for prototype development, sample validation and early-stage engineering needs.

BOM Services

Multi-line BOM matching with component supply, alternative suggestions and procurement follow-up.

Mass Production

Stable supply coordination for production preparation, batch delivery and long-term purchasing needs.

Experienced Team

Over 15 years of channel management, quality control, sales management and organization management experience.

WAVE2 Digital Storage Oscilloscope Technical Information

  • Specifications
  • FAQ
  • Hot Sale
  • Related Products

Specifications

Product Attributes
Attribute Value
Manufacturer:
CHINA

FAQ

1. How to order WAVE2 Digital Storage Oscilloscope on Flychip?

You can submit an RFQ directly on this page. Our sales team will review your quantity, delivery requirements and target price, then reply with a quotation as soon as possible.

2. How does Flychip verify the quality of WAVE2 Digital Storage Oscilloscope?

We work with qualified channels including international chip manufacturers and well-known distributors. Our team pays close attention to supplier review, traceability, product condition and quality control.

3. Are the price and inventory of WAVE2 Digital Storage Oscilloscope updated in real time?

Inventory and prices of electronic components may fluctuate frequently. The displayed data is for reference, and the final quotation will be confirmed by our sales team.

4. What payment methods are accepted?

Wire Transfer, PayPal, Alipay, WeChat, Credit Card, Western Union, MoneyGram and Escrow may be supported depending on the order and region.

5. How is shipping arranged?

We can arrange international shipping through DHL, UPS, FedEx, TNT and other logistics channels. Tracking information will be provided after shipment.

6. What is the return or replacement process for WAVE2 Digital Storage Oscilloscope?

Please contact our sales team within the specified period if there are quantity differences, wrong items, or clear external defects. The product should remain unused and in its original packaging.

7. Can I request technical support for WAVE2 Digital Storage Oscilloscope?

Yes. You can contact us for datasheet, package details, pin information and sourcing assistance related to WAVE2 Digital Storage Oscilloscope.

Related Products

WAVE2 Digital Storage Oscilloscope Sourcing & Technical Support

WAVE2 Digital Storage Oscilloscope is supplied by CHINA. This page provides key purchasing information including manufacturer, package, datasheet, stock reference, price reference and RFQ support.

As your reliable partner for semiconductor solutions, Flychip supports customers from research and development to mass production with electronic component supply, BOM sourcing, PCB, SMT and PCBA solutions.

Our sourcing partners include international chip manufacturers and well-known distributors. With rich experience in channel management, quality control and sales management, Flychip helps customers accelerate product development and delivery.

Part Number
WAVE2 Digital Storage Oscilloscope
Manufacturer
CHINA
Package
Category
Electrical

Quick RFQ Send your inquiry and our sales team will respond quickly.

Part Number
Quantity*
Price
Name*
Company*
Email*
Comments
Submitting...
Please wait while we submit your inquiry.

Tips

Please check your information and try again.

Submit BOM or RFQ Phone
+8615914913027
Email
irene@ic-flychip.net
WhatsApp
Flychip WhatsApp QR Code

Scan QR Code

Back to top