Current/Voltage Transducer Monitors

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Input Range Output Isolation Response Time Accuracy Voltage - Supply Mounting Type Termination Style Operating Temperature Approval Agency
10CP552

10CP552

SINGLE PHASE CURRENT TRANSDUCER

TransData, Inc.

1,736
RFQ
Datasheet - Bulk Active Current Transducer 0 ~ 10A 4 ~ 20mA - 400ms ±0.2% 100 ~ 130VAC Chassis Mount Screw Terminal -20°C ~ 70°C -
DN-848VI-80V

DN-848VI-80V

8-CH 80 VDC VOLTAGE ATTENUATOR

ICP DAS USA INC

4,732
RFQ
Datasheet DN-848VI Box Active Voltage Transducer ±80V ±10V 3000VAC (Test) - 1% 10 ~ 24VDC DIN Rail - -25°C ~ 75°C CE, FCC
P29001P2/01

P29001P2/01

CURRENT TRANSDUCER 1000 VDC

Knick

2,014
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±100V (Configurable) ±20mA, ±10V (Configurable) 1000VAC/DC (Working), 5400VAC (Test) 200µs ±0.1% 20 ~ 230VAC/DC DIN Rail Screw Terminal -25°C ~ 70°C cULus
P41000D1-S024

P41000D1-S024

CURRENT TRANSDUCER 2200 VDC

Knick

2,455
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±300mV (Configurable) ±2mA (Configurable) 2200VAC/DC (Working), 10000VAC (Test) 110µs ±0.1% 20 ~ 253VAC/DC DIN Rail Screw Terminal -10°C ~ 70°C UL
P41000D1-0121

P41000D1-0121

CURRENT TRANSDUCER 2200 VDC

Knick

4,710
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±100mV (Configurable) ±20mA, ±10V (Configurable) 2200VAC/DC (Working), 10000VAC (Test) 110µs ±0.1% 20 ~ 253VAC/DC DIN Rail Screw Terminal -10°C ~ 70°C UL
P41000D1

P41000D1

CURRENT TRANSDUCER 2200 VDC

Knick

3,187
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±10V (Configurable) ±20mA, ±10V (Configurable) 2200VAC/DC (Working), 10000VAC (Test) 110µs ±0.1% 20 ~ 253VAC/DC DIN Rail Screw Terminal -10°C ~ 70°C UL
P41100D1-0028

P41100D1-0028

CURRENT TRANSDUCER 3600 VDC

Knick

4,806
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±50mV 4 ~ 20mA 3600VAC/DC (Working), 15000VAC (Test) 110µs ±0.1% 20 ~ 253VAC/DC DIN Rail Screw Terminal -10°C ~ 70°C UL
P42001D3

P42001D3

VOLTAGE TRANSDUCER 2200 VDC

Knick

1,469
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±2200V (Configurable) ±20mA, ±10V (Configurable) 2200VAC/DC (Working), 10000VAC (Test) 110µs ±0.3% 20 ~ 253VAC/DC DIN Rail Screw Terminal -10°C ~ 70°C UL
P42000D3

P42000D3

VOLTAGE TRANSDUCER 2200 VDC

Knick

3,929
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±3600V (Configurable) ±20mA, ±10V (Configurable) 2200VAC/DC (Working), 10000VAC (Test) 110µs ±0.3% 20 ~ 253VAC/DC DIN Rail Screw Terminal -10°C ~ 70°C UL
P42000D2

P42000D2

VOLTAGE TRANSDUCER 2200 VDC

Knick

1,762
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±1200V (Configurable) ±20mA, ±10V (Configurable) 2200VAC/DC (Working), 10000VAC (Test) 110µs ±0.3% 20 ~ 253VAC/DC DIN Rail Screw Terminal -10°C ~ 70°C UL
P42000D3-S043

P42000D3-S043

VOLTAGE TRANSDUCER 2200 VDC

Knick

2,235
RFQ
Datasheet VariTrans Box Active Voltage Transducer ±2000V (Configurable) ±2mA (Configurable) 2200VAC/DC (Working), 10000VAC (Test) 110µs ±0.3% 20 ~ 253VAC/DC DIN Rail Screw Terminal -10°C ~ 70°C UL
T201DCH

T201DCH

TRMS Current Transducer, 50 AAC/

Seneca

2,392
RFQ
Datasheet T201 Bulk Active True RMS AC Voltage Transducer 0 ~ 50VAC, 0 ~ 50VDC (Configurable) 0 ~ 10VDC 3000VAC 800ms 1% 10 ~ 28VDC DIN Rail Spring Terminal -10°C ~ 60°C CE, UL
DVT-1000-420

DVT-1000-420

TRANSDUCER 0-1000V:4-20MA 0.5%

Magnelab, Inc.

4,833
RFQ
Datasheet DVT Tape & Box (TB) Active DC Voltage Transducer 0 ~ 1000VDC 4 ~ 20mA 4500V (Test) 200ms 0.005% 15 ~ 48VDC DIN Rail Screw Terminal -30°C ~ 70°C -
10VP552

10VP552

SINGLE PHASE VOLTAGE TRANSDUCER

TransData, Inc.

2,024
RFQ
Datasheet - Bulk Active Voltage Transducer 0 ~ 180V 4 ~ 20mA - 400ms ±0.2% 100 ~ 130VAC Chassis Mount Screw Terminal -20°C ~ 70°C -
CR4550-500

CR4550-500

TRANSDUCER VOLTAGE 24VDC

CR Magnetics Inc.

4,044
RFQ
Datasheet CR4500 Bulk Active True RMS AC Voltage Transducer 0 ~ 500VAC 0 ~ 5VDC 2500VDC 250ms 0.5% 24VDC DIN Rail Screw Terminal 0°C ~ 60°C CE, cURus
TPRVM001

TPRVM001

TESYS ISLAND VOLTAGE INTERFACE M

Schneider Electric

4,445
RFQ
Datasheet - Box Active DC Voltage Transducer - - - - ±5% 24VDC DIN Rail Spring Terminal -10°C ~ 60°C CSA, EAC, UL
ISOBLOCK I-FG-1C (6A 5V)

ISOBLOCK I-FG-1C (6A 5V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

1,092
RFQ
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 6A ±5V 1200V (Working) 5µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ISOBLOCK I-FG-1C (15A 5V)

ISOBLOCK I-FG-1C (15A 5V)

TRANSDUCER CURRENT 9-28VDC

Verivolt LLC

3,126
RFQ
Datasheet IsoBlock I-FG Box Active Current Transducer 0 ~ 15A ±5V 1200V (Working) 5µs ±0.2% 9 ~ 28VDC DIN Rail Spring Terminal -25°C ~ 70°C -
ENTUBE SE (100V 10V)

ENTUBE SE (100V 10V)

TRANSDUCER VOLTAGE DIVIDER

Verivolt LLC

3,356
RFQ
Datasheet Entube SE Box Active Voltage Transducer ±100V ±10V - - ±0.2% - DIN Rail Spring Terminal -25°C ~ 70°C -
ENTUBE SE (500V 5V)

ENTUBE SE (500V 5V)

TRANSDUCER VOLTAGE DIVIDER

Verivolt LLC

2,401
RFQ
Datasheet Entube SE Box Active Voltage Transducer ±500V ±5V - - ±0.2% - DIN Rail Spring Terminal -25°C ~ 70°C -
Total 1041 Record«Prev12345678...53Next»
Submit BOM or RFQ Phone
+8615914913027
Email
irene@ic-flychip.net
WhatsApp
Flychip WhatsApp QR Code

Scan QR Code