Valves and Control

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Function Actuator Type Operating Pressure Orifice Diameter Fluid Type Connection Method For Use With/Related Products Mounting Type Features
VUVS-L20-M32C-MZD-G18-F7-1C1

VUVS-L20-M32C-MZD-G18-F7-1C1

SOLENOID VALVE

Festo Corporation

4,616
RFQ
Datasheet VUVS Bulk Active Solenoid Valve 3/2 Normally Closed - -1 ~ 145 PSI (-0.1 ~ 10 bar) - Air Threaded G1/8" Solenoid Valve Chassis Mount Supply Voltage 24VDC
VUVS-L20-M32C-AZD-G18-F7-1C1

VUVS-L20-M32C-AZD-G18-F7-1C1

SOLENOID VALVE

Festo Corporation

4,679
RFQ
Datasheet VUVS Bulk Active Solenoid Valve 3/2 Normally Closed - -1 ~ 145 PSI (-0.1 ~ 10 bar) - Air Threaded G1/8" Solenoid Valve Chassis Mount Supply Voltage 24VDC
VUVS-L20-M32C-MD-G18-F7-1C1

VUVS-L20-M32C-MD-G18-F7-1C1

SOLENOID VALVE

Festo Corporation

4,548
RFQ
Datasheet VUVS Bulk Active Solenoid Valve 3/2 Normally Closed - 36 ~ 145 PSI (2.5 ~ 10 bar) - Air Threaded G1/8" Solenoid Valve Chassis Mount Supply Voltage 24VDC
VUVS-L20-M32C-AD-G18-F7-1C1

VUVS-L20-M32C-AD-G18-F7-1C1

SOLENOID VALVE

Festo Corporation

3,703
RFQ
Datasheet VUVS Bulk Active Solenoid Valve 3/2 Normally Closed - 36 ~ 145 PSI (2.5 ~ 10 bar) - Air Threaded G1/8" Solenoid Valve Sub-Base Mount Supply Voltage 24VDC
VUVG-B18-M52-RZT-F-1P3

VUVG-B18-M52-RZT-F-1P3

SOLENOID VALVE

Festo Corporation

3,872
RFQ
Datasheet VUVG Bulk Active Solenoid Valve 5/2 - -1 ~ 145 PSI (-0.1 ~ 10 bar) - Air Threaded Solenoid Valve Chassis Mount Supply Voltage 24VDC
HGL-1/8-1/8-B

HGL-1/8-1/8-B

PILOTED CHECK VALVE

Festo Corporation

3,252
RFQ

-

HGL Bulk Active Non-Return Valve (Check Valve) One-Way - 7 ~ 145 PSI (0.5 ~ 10 bar) - Air Threaded G1/8" Control Valve Free Hanging (In-Line) -
MHJ9-MF

MHJ9-MF

SOLENOID VALVE

Festo Corporation

3,646
RFQ

-

MHJ9 Bulk Active Solenoid Valve 2/2 Normally Closed - 7 ~ 87 PSI (0.5 ~ 6 bar) - Air Threaded Solenoid Valve Sub-Base Mount Supply Voltage 24VDC
MHJ9-HF

MHJ9-HF

SOLENOID VALVE

Festo Corporation

3,472
RFQ

-

MHJ9 Bulk Active Solenoid Valve 2/2 Normally Closed - 7 ~ 87 PSI (0.5 ~ 6 bar) - Air Threaded Solenoid Valve Sub-Base Mount Supply Voltage 24VDC
MHJ9-LF

MHJ9-LF

SOLENOID VALVE

Festo Corporation

1,423
RFQ

-

MHJ9 Bulk Active Solenoid Valve 2/2 Normally Closed - 7 ~ 116 PSI (0.5 ~ 8 bar) - Air Threaded Solenoid Valve Sub-Base Mount Supply Voltage 24VDC
MHJ9-HF/LP

MHJ9-HF/LP

SOLENOID VALVE

Festo Corporation

3,700
RFQ

-

MHJ9 Bulk Active Solenoid Valve 2/2 Normally Closed - 7 ~ 58 PSI (0.5 ~ 4 bar) - Air Threaded Solenoid Valve Sub-Base Mount Supply Voltage 24VDC
Total 6278 Record«Prev1... 9596979899100101102...628Next»