AC DC Configurable Power Supply Chassis

Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status User Configuration Type Number of Positions Voltage - Input Power (Watts) Voltage - Isolation Efficiency Features Operating Temperature Size / Dimension Height Approval Agency Standard Number
XLCC0

XLCC0

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

4,959
RFQ
Datasheet Xgen, XL Box Active - Standard 4 85 ~ 264 VAC 600 W 3 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XLD-D1

XLD-D1

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

2,213
RFQ
Datasheet Xgen, XL Box Active - Standard 4 85 ~ 264 VAC 750 W 4 kV 90% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.55" L x 3.50" W (268.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XKB-02

XKB-02

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

3,785
RFQ
Datasheet Xgen, XK Box Active - Standard, Low Noise 4 85 ~ 264 VAC 400 W 3 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XLD-D3

XLD-D3

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

2,552
RFQ
Datasheet Xgen, XL Box Active - Standard 4 85 ~ 264 VAC 750 W 4 kV 90% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.55" L x 3.50" W (268.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
UX4-D2

UX4-D2

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

1,523
RFQ
Datasheet UltiMod, UX Box Active - Medical 4 85 ~ 264 VAC 600 W 4 kV 90% Fan Fail, Temperature Alarm -40°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XRB-01

XRB-01

CONFIG POWER CHASSIS

EXCELSYS / Advanced Energy

2,971
RFQ
Datasheet Xgen, XR Box Active - Medical, Low Noise 4 85 ~ 264 VAC 400 W 4 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XLDSD3

XLDSD3

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

1,726
RFQ
Datasheet Xgen, XL Box Active - Standard 4 85 ~ 264 VAC 750 W 4 kV 90% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.55" L x 3.50" W (268.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
XLCCD1

XLCCD1

CONFIG POWER CHASSIS 600W 4 SLOT

EXCELSYS / Advanced Energy

1,396
RFQ
Datasheet Xgen, XL Bulk Active - Standard 4 85 ~ 264 VAC, 120 ~ 380 VDC 600 W 3 kV 89% Conformal Coating, Fan Fail, Reverse Fan, Ruggedized, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
UX6-D2

UX6-D2

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

4,784
RFQ
Datasheet UltiMod, UX Box Active - Medical 6 85 ~ 264 VAC 1200 W 4 kV 90% Fan Fail, Temperature Alarm -40°C ~ 70°C (With Derating) 10.24" L x 5.00" W (260.0mm x 127.0mm) 1.59" (40.40mm) CE, cURus -
XMC-02

XMC-02

CONFIGURABLE POWER SUPPLY

EXCELSYS / Advanced Energy

3,792
RFQ
Datasheet Xgen, XM Box Active - Medical 4 85 ~ 264 VAC 600 W 4 kV 89% Fan Fail, Temperature Alarm -20°C ~ 70°C (With Derating) 10.24" L x 3.50" W (260.0mm x 89.0mm) 1.59" (40.40mm) CE, cURus -
Total 1450 Record«Prev1... 56789101112...145Next»
Submit BOM or RFQ Phone
+8615914913027
Email
irene@ic-flychip.net
WhatsApp
Flychip WhatsApp QR Code

Scan QR Code

Back to top